This metric nomenclature is also accepted in the most recent E version of the Standard. Federal Standard E is used domestically. The cleanroom classification standards FS E and ISO require specific particle count measurements and calculations to classify the cleanliness level of a cleanroom or clean area. In the UK, British Standard is used to classify cleanrooms. Cleanrooms are classified according to the number and size of particles permitted per volume of air.
The standard also allows interpolation, so it is possible to describe e. Small numbers refer to ISO standards, which specify the decimal logarithm of the number of particles 0. For that reason, there is no such thing as zero particle concentration. Ordinary room air is approximately class 1,, or ISO 9.
However, as the need for international standards grew, the ISO established a technical committee and several working groups to delineate its own set of standards. FSE contains six classes, while the ISO classification system adds two cleaner standards and one dirtier standard see chart below. The "cleanest" cleanroom in FSE is referred to as Class 1; the "dirtiest" cleanroom is a class , ISO cleanroom classifications are rated according to how much particulate of specific sizes exist per cubic meter see second chart.
The "cleanest" cleanroom is a class 1 and the "dirtiest" a class 9. By law, Federal Standard E can be superseded by new international standards. It is expected that E will be used in some industries over the next five years, but that eventually it will be replaced internationally by ISO In cleanrooms, particulate concentration changes over time — from the construction and installation of equipment to its operational status.
ISO delineates three cleanroom classification standards: as-built, at-rest and operational. As instruments and equipment are introduced and particulates rise, an "as-built" cleanroom becomes an "at-rest" cleanroom.
When people are added to the matrix, particulate levels rise still further in the "operational" cleanroom. ISO describes the type and frequency of testing required to conform to certain standards. The following tables indicate mandatory and optional tests. Many are in the final voting stage and can be legally used in the trade see chart.
A critical factor in cleanroom design is controlling air-change per hour ACH , also known as the air-change rate, or ACR. This refers to the number of times each hour that filtered outside air replaces the existing volume in a building or chamber. In a normal home, an air-conditioner changes room air 0. In a cleanroom, depending on classification and usage, air change occurs anywhere from 10 to more than times an hour. To meet optimal standards, ACR must be painstakingly measured and controlled.
And there is some controversy. In an appendix to its ISO cleanliness standard, the International Standards Organization addressed applications for microelectronic facilities only. ISO classes 6 to 8; Federal Standards 1,, 10, and , The appendix contained no ACR standards for pharmaceutical, healthcare or biotech applications, which may require higher ACR regulations. According to current research, case studies and experiments, using an ACR range rather than one set standard is a better guideline for cleanliness classification.
This is true because the optimal ACR varies from cleanroom to cleanroom, depending on factors such as internal equipment, staffing and operational purpose. Everything depends on the level of outside contaminants trying to enter the facility versus the level of contaminants being generated on the inside. The breadth of these ranges reflects how dramatically people and processes affect cleanliness. Low-end figures within each contamination class generally indicate air velocity and air change requirements for an as-built or at-rest facility — where no people are present and no contaminating processes under way.
When there are people and processes producing contaminants, more air changes are required to maintain optimal cleanliness standards. For instance, some manufacturers insist on as many as air changes per hour to meet Class 10 standards. Determining the appropriate number of air changes for a particular application requires careful evaluation of factors such as the number of personnel, effectiveness of garbing protocol, frequency of access, and cleanliness of process equipment.
Compressive strength refers to the ability of a rigid foam plastic board to resist deformation and maintain its shape when subjected to a force or load. Common construction applications require compressive strengths adequate for polyisocyanurate to maintain its shape during installation, as well as during use.
Practically speaking, wall applications require p olyiso to support flexible siding materials; for roofing projects , it must withstand limited installation traffic, support fastener loads, and sustain the total roofing system. Polyisocyanurate insulation can contribute to a more fire-safe home or building after renovation work. Additionally, p olyiso foam insulation stays intact during fire exposure in ASTM E 84, Standard [Tunnel] Test Method for Surface Burning Characteristics of Building Materials, forming a protective char layer and remaining in place to meet building code requirements.
Typically, polyisocyanurate is used to insulate the entire wall including the framing , thereby significantly reducing heat loss through both convection and conduction. Additionally, properly insulating a structure with Polyiso foam insulation can decrease condensation in the walls, potentially lowering moisture-related problems.
When properly specified and installed, polyisocyanurate insulating sheathing can be one of the best values available for those upgrading or renovating a home or facility. Polyiso for Exterior Insulation When re-siding a building, vinyl siding can be placed over a layer of p olyiso installed atop the existing exterior cladding.
Polyisocyanurate can also be used with exterior products such as fiber cement siding, wood siding, stucco, and metal siding. Polyisocyanurate Foam for Interior Wall Insulation For interior wall refinishing projects, a layer of p olyiso insulation can be installed prior to the addition of new gypsum wallboard.
Basement Insulation Non-insulated basement walls can be a significant source of heat loss. When finishing a basement, a layer of polyisocyanurate sheathing can be placed over the interior wall and covered with mm 0.
Insulating Attics With Polyiso Foam When turning an attic into a living space, one can place Polyiso on the interior over the studs before installing gypsum board. It can also be practical to fill the cavities with p olyiso insulation. Home-Addition Insulation Should the renovation include adding square footage to the home, such as a new family room or master bedroom, using polyisocyanurate insulation as the exterior sheathing can provide the homeowner with energy-efficient construction and potentially add to the long-term thermal performance of the entire home.
Polyisocyanurate Foam Insulation — A Renovation Weapon to Combat Rising Energy Costs During most renovations, people tend to focus on the design of the home and its most noticeable features, such as light fixtures, countertops , and wall colors. Specifying Polyiso insulation Polyisocyanurate Polyiso insulation is an excellent choice for a variety of renovation applications because of its excellent energy conserving qualities.